Excellent plc controller supplier: Object-oriented principle: That is, according to the identity characteristics and work nature of the operator, design a human-machine interface that is compatible and friendly. According to their work needs, it is appropriate to display prompts, guidance and help information in pop-up windows, so as to improve the level of user interaction and efficiency. HMI, whether for the field controller or for the upper monitoring and management, the two are closely interconnected, they monitor and manage the field equipment objects are the same, so many field equipment parameters are shared between them and passed to each other. The standardized design of the human-machine interface should be the future development direction, because it really reflects the easy-to-configure, simple, and practical principles of the base, fully expressing the human-centered design concept. A variety of industrial control configuration software and programming tools provide powerful support for the production of a beautiful human-machine interface, and the larger and more complex the system, the more it can reflect its superiority. Discover extra info on hmi touch screen.
System Reliability Requirements: The reliability of the general system PLC can be met. For systems with high reliability requirements, consider whether to use redundant systems or hot standby systems. PLC should be unified possible. Mainly consider the following three aspects: The model is unified, and its modules can be used as backup for each other, which is convenient for the procurement and management of spare parts. The model is unified and its function and use method are similar, which is conducive to the training of technical forces and the improvement of technical level. The model is unified, its external equipment is universal, resources can be shared, easy to network communication, and it is easy to form a multi-level distributed control system after being equipped with a computer.
Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects.
The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.
In 2022, in order to meet the new needs of customers and the market, our MochuanDrives merged with a professional manufacturer of highly customized servo motors, with more than 20 years of experience in research and development, manufacturing and service of servo motors and brushless motors, especially good at tailor-made high-end motors with special specifications from scratch, until the stable manufacturing of large quantities. With NO MOQ, before large quantities needing to get 100% stable quality confirmation from our customers. Find additional information at mochuan-drives.com.
Typically, a heartbeat detection is used to define the BOOL, the HMI sets this point at a fixed frequency and the PLC resets when it receives a signal that the point is on. If no signal is received for that point to turn on for a period of time, e.g. 5s, the communication is considered broken. The PLC’s memory clock byte is passed to the touch panel interface, which uses a script to assign the value of this byte to an address in another PLC, which then determines whether the two scan cycles of the returned byte are the same. If so, the communication is interrupted.
This type touchscreen panel support 7inch, 9.7inch, 17inch, 22inch and 32inch, is enough to select suitable model for the project from application and cost. There are two operating temperature -10°C to 60°C and -20°C to 70°C. And all the size and model is to support ethernet, 2pcs rs485 or 2pcs rs232 is in optional. Adpoting industrial grade high quality components, high protection level design, comprehensive three-proof coating, no matter the wet underground mine, high temperature gobi or corrosive gas, oil mist or dust factory environment, can easily cope with, easy to handle.
There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.
In the wisdom of industry, electrical cabinet control equipment is suitable for electric facilities, chemical plants, mechanical plants, plant electrical control, network companies electrical control, site large electrical equipment control, etc., to provide convenient electrical management services for the majority of enterprises. Whether it is a small or large electrical cabinet control equipment, it can easily manage the whole company, the whole enterprise, the whole factory electrical equipment.
The human-machine interface is the central link in the human-machine system, mainly by the safety engineering sub-discipline safety ergonomics to study and propose solutions based on the safety engineering equipment engineering, safety management engineering and safety systems engineering to study specific solutions and measures safety ergonomics. It realizes the conversion between the internal form of information and the acceptable form for human beings.