Wed. May 8th, 2024

Dry type transformer supplier from China: Strengthen monitoring and maintenance: In order to avoid the adverse impact of the failure of the main transformer cooler on the transformer, the monitoring and maintenance of the cooler can be strengthened. Regularly inspect and maintain the cooler, and find and solve problems in time, which can improve the reliability and stability of the cooler. Temporary emergency measures: During the troubleshooting period, some temporary emergency measures can be taken, such as reducing the load of the main transformer, increasing ventilation, etc., to reduce the temperature of the transformer and ensure the safe operation of the transformer. In short, for the failure of the main transformer cooler, it is necessary to take timely measures to deal with it to ensure the normal operation and safety of the transformer. The specific treatment method needs to be selected according to the structure of the cooler and the cause of the failure. Find more details at https://www.canwindg.com/products-20763.

Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.

Power quality plays a crucial role in the performance and longevity of distribution transformer substation. Poor power quality can lead to increased losses, reduced efficiency, and shorter equipment lifespan. Therefore, effective strategies for power quality management are indispensable for the optimal operation of distribution transformers. Harmonic currents, particularly those of higher frequencies, can significantly affect the performance of transformers. These currents are produced by non-linear loads such as computers, variable speed drives, and certain types of lighting systems, causing distortions in the sinusoidal waveform of the electrical supply.

CANWIN AUTOMATICEQUIPMENT CO.,LTD is a global leading foil winding machine supplier & manufacturer with over 20 years of experiences.Ribbon foil winding machine has unique appearance, convenient operation, intuitive data display, high degree of automation, and is well received by users. This foil winding machine is widely used in oil-immersed transformer, dry transformer, special transformer and reactor production required. Foil coils are of different thicknesses copper or aluminum foil as a conductor, with wide ribbon insulation material as the insulation between layers, with narrow ribbon insulation material as the end insulation, completed winding one time, forming a coil. The inner and outer leads of the coil are welded and wrapped up at the same time.

Independently developed a series of high -speed cut to length line which up to 128 pcs/mins, which increased the cutting speed 2-3 times Independently developed the bridge automatic cutting and automatic lamination cut to length line, which can realize 20 large transformer core column level for automatic lamination, this project has won the record and nomination of Guangdong major research and development projects; Participated in the application and filing of the major science and technology special project of intelligent robot and equipment manufacturing”in the research and development plan of key fields in Guangdong province in 2018-2019. The company has been constantly extending the innovation chain around the guiding ideology of industrial chain deploy innovation chain.

Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.

The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.

The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. Find even more information at https://www.canwindg.com/

Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.

The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.

Dry-type transformers are widely used in local lighting, high-rise buildings, airports, dock CNC machinery and equipment, etc. Simply put, dry-type transformers refer to transformers whose iron cores and windings are not impregnated with insulating oil. The relevant technical parameters of dry-type transformers include: Rated capacity (kVA): The capacity that can be delivered during continuous operation at rated voltage and rated current. Rated voltage (kV): The working voltage that a transformer can withstand during long-term operation.